Last Updated on August 12, 2026

TL;DR: Understanding the different types of autoclaves is essential for selecting the right sterilization solution for your laboratory or clinical environment. This guide breaks down the most common types of autoclave sterilization, explaining how each system works and what materials they are best suited for.

Key takeaways include:

  • The two types of autoclaves based on sterilization method: gravity displacement and vacuum-assisted
  • How Class N, Class S, and Class B autoclaves differ in air removal, steam penetration, and load compatibility
  • Which different types of autoclave machines are best suited for solid, porous, wrapped, or hollow loads
  • The advantages and limitations of each autoclave class across laboratory and clinical settings
  • How autoclave selection aligns with application requirements and regulatory standards

What is an autoclave?

An autoclave is a steam sterilizer that uses saturated steam under pressure to destroy microorganisms on laboratory materials, instruments, liquids, and waste. Autoclaves differ mainly in how they remove air from the chamber and allow steam to reach the load.

Laboratory autoclaves are available in several configurations, each designed for specific sterilization requirements. Differences in air removal, steam penetration, and validated load types affect which system is appropriate for laboratory, clinical, or research applications.

This guide explains how gravity displacement, Class N, Class S, and Class B autoclaves differ, helping you identify the type that best matches your materials, workflow, and compliance requirements. You can also review five factors to consider when choosing an autoclave.

Comparison of common autoclave types

Autoclaves are commonly grouped by how they remove air from the chamber and
allow steam to reach the load. The table below summarizes the main
differences between gravity, vacuum, and Class S autoclaves.

Autoclave typeAir-removal methodCommon applicationsMain advantagesLimitations
Gravity displacement / Class NSteam enters the chamber and pushes heavier air downward and out
through the drain.
Liquids, culture media, glassware, laboratory waste, and solid
unwrapped instruments.
Simple operation, dependable performance, and fewer complex
components.
Generally not suitable for wrapped, porous, or narrow hollow loads.
Pre-vacuum / Class BA vacuum pump removes air before steam enters the chamber.Wrapped instruments, porous materials, textiles, and hollow
instruments.
Improved air removal and steam penetration for complex loads.More complex equipment, higher maintenance needs, and greater cost.
Class SUses a manufacturer-defined air-removal and sterilization process.Specific wrapped, unwrapped, porous, or hollow loads approved by the
manufacturer.
Designed for selected applications that fall between Class N and
Class B capabilities.
Load compatibility varies by model and must be confirmed with the
manufacturer.

How different types of autoclaves work

The primary distinction among the different types of autoclave machines is their sterilization method. Broadly speaking, there are two types of autoclaves based on sterilization method:

  • Gravity displacement autoclaves
  • Vacuum-induced/pre-vacuum autoclaves

Some laboratory autoclaves incorporate features from both gravity displacement and vacuum-assisted sterilization to support specific applications. Although all steam autoclaves use saturated steam under pressure, the method of air removal affects steam penetration and the types of loads each system can process effectively. Learn more about the importance of steam in laboratory autoclaves and what can and cannot be autoclaved.

Class N gravity autoclaves: simple and dependable

A diagram that demonstrates how Amuza vertical autoclaves function.Class N autoclaves commonly use gravity displacement to remove air from the chamber. Their simple design, dependable operation, and relatively low maintenance requirements make them common in laboratory settings.

Steam generation and circulation

Gravity autoclaves work by pumping steam into the autoclave chamber, which displaces ambient air and forces it out through exhaust valves. Once the air is removed, saturated steam surrounds the load to achieve sterilization.

Suitable materials

Due to their use of gravity-based air removal, Class N autoclaves are commonly used for compatible liquids, glassware, laboratory waste, and solid, non-porous unwrapped items, such as:

  • Laboratory glassware
  • Culture media
  • Biohazard waste
  • Unwrapped metal instruments
  • Laboratory utensils

They are not recommended for sterilizing porous loads, wrapped items, or surgical instruments with internal channels. With these materials, trapped air can prevent effective steam penetration.

Use cases

Class N autoclaves are commonly used where routine sterilization involves liquids, culture media, glassware, laboratory waste, and unwrapped solid items. Typical settings include:

  • Academic and research laboratories
  • Biotechnology laboratories
  • Pharmaceutical research and quality control laboratories
  • Food and environmental testing laboratories
  • Teaching laboratories

They are particularly well suited for laboratories that do not routinely sterilize wrapped, porous, or narrow-lumen instruments.

Limitations

Without a vacuum phase, Class N autoclaves cannot reliably sterilize:

  • Porous materials
  • Layered or wrapped loads
  • Hollow instruments with lumens

Standards and regulations

While suitable for many applications, specific healthcare and laboratory settings may require autoclaves that meet more stringent sterilization standards. These regulated environments may necessitate the use of Class B autoclaves.

Class B vacuum autoclaves: deeper sterilization for challenging media

Class B autoclaves are designed for applications requiring reliable steam penetration into wrapped, porous, and hollow loads.

Vacuum functionA diagram that demonstrates how Amuza horizontal autoclaves function.

Unlike gravity systems, Class B autoclaves use a powerful vacuum pump to remove air from both the chamber and the load before steam is introduced. By creating a pre-vacuum and evacuating the ambient air within the chamber, high-temperature steam can fully penetrate and sterilize even the most challenging items.

Steam penetration

Creating a vacuum before and during the sterilization cycle allows for effective steam penetration throughout the load, including:

  • Wrapped instruments
  • Hollow instruments
  • Porous materials
  • Laboratory textiles
  • Certain liquid containers where vacuum-assisted air removal improves steam penetration

Versatility

Class B systems are designed for a broad range of load types, including wrapped, porous, and hollow items. This makes them well suited for medical, dental, and laboratory environments where vacuum-assisted air removal and deeper steam penetration are required.

Standards compliance

These autoclaves are designed to comply with rigorous international sterilization standards, including EN 13060 for small steam sterilizers, where applicable. This compliance ensures that Class B autoclaves can meet the demands of high-standard healthcare practices.

Efficiency and environmental considerations

Modern Class B autoclaves are designed with efficiency in mind regarding energy consumption and water usage. Some models incorporate eco-friendly features to minimize their environmental impact.

Class S: the in-between option

Class S autoclaves bridge the gap between Class N and Class B systems by providing enhanced air removal while remaining validated only for the load types specified by the manufacturer.

They can sterilize a broader range of items than Class N, including some wrapped materials and products with hollow sections. This makes them a good fit for environments with more varied sterilization needs that don’t require the full performance of a Class B autoclave.

Sterilization capabilities

Class S autoclaves can sterilize:

  • Solid instruments
  • Certain porous materials
  • Some hollow instruments
  • Selected wrapped items (depending on model specifications)

Air removal techniques

Instead of full vacuum systems, Class S autoclaves use techniques such as steam pulsing to improve air removal beyond basic gravity displacement. This allows for better penetration of steam into the load when compared with Class N autoclaves.

Standards and regulations

Class S autoclaves meet specific international standards but may not satisfy all requirements mandated for Class B sterilization. Verification against application-specific regulations is essential. Unlike Class B autoclaves, Class S systems are validated only for the specific load types defined by the manufacturer.

Use cases

Class S autoclaves are commonly used in dental practices, smaller medical facilities, and laboratories that need more flexibility than Class N autoclaves can provide but do not require the full capabilities of Class B autoclaves. They are particularly useful for practices that need to sterilize wrapped items or instruments with small lumens.

Which autoclave type is right for your application?

The most appropriate autoclave depends on the materials you sterilize, your laboratory workflow, and any regulatory requirements. The table below provides a general comparison of common laboratory applications.

ApplicationRecommended autoclave typeReason
Laboratory glasswareClass N (Gravity)Simple solid loads allow effective steam penetration using gravity displacement.
Culture media and aqueous solutionsClass N (Gravity)Commonly used for routine laboratory sterilization of liquids.
Biohazard laboratory wasteClass N (Gravity)Suitable for many laboratory waste sterilization procedures.
Wrapped instrumentsClass BVacuum-assisted air removal improves steam penetration through packaging.
Porous materials or laboratory textilesClass BVacuum cycles remove trapped air before sterilization.
Hollow instrumentsClass BVacuum-assisted air removal supports steam penetration into internal channels.
Selected wrapped, porous, or hollow loadsClass S or Class BSuitability depends on the manufacturer’s validated load specifications.
Free planning resource

Planning for a new autoclave?

Use our laboratory autoclave planning checklist to review load size,
capacity, installation requirements, utilities, and workflow before
comparing equipment.

Choosing the right autoclave for your needs

Selecting the right autoclave begins with identifying which class best matches your sterilization needs.

Beyond autoclave class, laboratories should also consider chamber capacity, installation requirements, programmable cycles, cooling performance, validation options, and the types of materials sterilized each day. The best autoclave is the one that supports your workflow while meeting your sterilization requirements.

    • Class B autoclaves are ideal for medical, dental, and research environments requiring comprehensive sterilization across diverse materials.
    • Class S autoclaves offer a balance of flexibility and performance for mixed-use settings.
    • Class N gravity autoclaves are a practical choice for compatible liquids, glassware, waste, and unwrapped solid items. TOMY SX-Series gravity displacement autoclaves are designed for laboratories sterilizing liquids, media, glassware, and laboratory waste. Their compact footprint, no-plumbing installation, and programmable cycles make them well suited for research and quality control laboratories.

By understanding the different types of autoclaves, you can confidently choose equipment that best aligns with your workflow.

The best autoclave type depends on the load. Gravity autoclaves are a dependable choice for many laboratory liquids, glassware, solid instruments, and waste loads, while vacuum systems may be required for wrapped, porous, or hollow items.

The Complete Guide to Autoclave Prices: Unveiling the True Cost of Ownership

Previous Article

Why Top-Loading Autoclaves Are The Ideal Solution for Bioreactor and Fermentor Sterilization

Next Article

Recent Blogs & Vlogs

Why a Biological Indicator (BI) Test Can Fail Even When the Autoclave Cycle Completed

Why a Biological Indicator (BI) Test Can Fail Even When the Autoclave Cycle Completed

If your autoclave cycle finishes normally but your BI test comes back positive, the cause is often not a malfunction. In many lab sterilization scenarios, the issue is heat transfer time lag—when the chamber reaches the set temperature before the load does. What the autoclave measures (and what it doesn’t) During operation, the autoclave’s temperature […]

Signs Your Lab Has Outgrown Its Autoclave (And What to Do Next)

Signs Your Lab Has Outgrown Its Autoclave (And What to Do Next)

In many labs, an autoclave doesn’t suddenly fail. Instead, it slowly becomes the bottleneck. As research programs expand, staff increases, and protocols diversify, the demands placed on sterilization equipment often grow faster than the equipment itself. What once worked smoothly for a small team can quietly turn into daily scheduling conflicts, delayed experiments, and inefficient […]